Steel body slip line common troubleshooting methods

Steel slide in the use of more or less will encounter a variety of problems, the following we describe the different problems corresponding to the treatment.

One problem: the steel slide rail sparks.

The main reason: bad brush surface and rail contact;

Treatment: Test rail joints, appropriate wear brush to ensure 60% contact area.

Question two: work slippery slide big.

The main reason: fork can not absorb the transmission error, poor linearity of the front guide, mention hanging rack loose;

Remedy: Amend the tractor, so that it can freely absorb the transmission error, adjust the straightness of the guide rail, and tighten the rack mounting screw.

Question three: scratches the side of the brush.

Main reasons: brush wear, slip-line collector set as not correct; drag side fork force transmission is too large;

Remedy: Replace and correct the spring pressure. Change the towing fork or modify the towing fork.

Question four: collector shell scratches.

Main reasons: rail deformation, collector poor positioning;

Approach: According to the fault 2 processing, increase the stereotypes folder; adjust the collector.

Five questions: trolley line collector walking a big abnormal noise.

The main reason: the current is too large; joints are not smooth;

Approach: Increase the number of collectors; re-install the rail connection.

Question six: brush wear fast

The main reason: the joint is not smooth; the flow is too large; the spring pressure is big;

Remedy: re-connect the rail as required; increase the number of collectors; replace, correct spring pressure.

Question seven: slide the line power.

Main reasons: brush climbing in the catheter; brush wear serious, can not touch the conductor; conductor connector is not flat; single collector use;

Treatment methods: Detect whether the collector is worn seriously, replace the collector; replace the brush; readjust the connection node; adopt double brush collector; readjust tighten the connection screw.

Question eight: rail deformation, blocked collector movement.

The main reason: the ambient temperature is too high; mention rack spacing or loose;

Treatment: local use of insulation panels, outdoor sun visor; increase the number of trolley wire rack to mention, to correct the catheter, and tighten the screws.

The above is the fault of the steel slide, as well as the cause and treatment of the failure, I hope this content is helpful to you.